| Error: "Pervasive Status Code 94." (incorrect Pervasive settings in Windows Registry) |
Resolution | [BCB:4:Operating system warning:ECB]
This applies to Sage 300 CRE version 12.1 and older.
Change the registry settings for Pervasive
Change the SAT entries registry value for Pervasive as follows:
- On the workstation, use the Windows Registry Editor and browse to the following subkey depending on the version of Pervasive that you have installed as follows:
- Delete any SAT entries in the registry. For example, if you see SatEntry0, or SatEntry1, right-click each one and select Delete.
- Set the value to 0 for NumSatEntries. Double-click NumSatEntries, type 0 in the Value data box and click OK.
- Exit the Registry Editor.
DocLink: Sage 300 Construction and Real Estate and Sage Estimating Required Windows Permissions DocLink: Error: "Pervasive Status Code 94". (Troubleshooting)
|
|