Reset Application Server Configuration to default settings
Description
Cause
Resolution
  1. Have all users exit Sage 100 ERP.
  2. Stop the Sage 100 ERP Application Service.
  3. Open …MAS90\Home\Lib\_AppServ\.
  4.  Rename these files:
    • apps.pvk → apps.old
    • locate.pvk → locate.old
    • server.pvk → server.old
    • sessions.pvk → sessions.old
  5. Open ...MAS90\Home.
  6. Double-click pvxwin32.exe.
  7. Click OK.
  8. Type: o=new("sy_installation")
    •  NOTE: The command starts with an "o" (as in oxygen), not a zero. 
  9. Press Enter.
  10. Type: o'configuremas200("C:\Sage...\MAS90")
    •  CAUTION: Enter the correct path to the MAS90 directory on the client’s system. The command starts with an "o" (as in oxygen), followed by a single quote. 
  11. Press Enter
    • NOTE:

      If successful, you will receive either a 1 or blank - If you receive any other value, the procedure failed.

       
  12. Open Start, All Programs, Sage, Sage 100 ERP, Application Server Configuration.
  13. Select the Server tab.
  14. Enter the Socket (Port) number.
  15. Deselect the KeepAlives option on Server Tab.
  16. Set Re-Connect to None on Clients tab
  17. Select Apply.
  18. Select Exit.
  19. Start the Sage 100 ERP Application Service.